  SLOTTED SIDE MOUNTING RAP-TIE NOTES

(i) The design values reflect both the windward and leeward capacity of the Slotted Side Mounting Rap-Tie system, with the governing values listed.

(ii) The tie system recommended design load value was formulated using working stress design following the procedures of CSA CAN3-A370-M94 "Connectors for Masonry", ACI/ASCE/TMS/518 and U.B.C. The value has been corrected to account for test result variation, and reflect a factor of safety of 2.25 (i.e. 75% of 3.0), as per Table 3 (A370).

(iii) The allowable mortar pull-out design load for the V-Tie™ embedded at the centerline of 90 mm (3.5") brick veneer utilizing Type M, S or N mortar, exceeds or equals the recommended design loads listed above.

(iv) The above design values relate to the capacity of the FERO tie components. A compatible fastener (or fasteners) capable of resisting the design load must be selected.

(v) The above design values are based on test results utilizing a 140 mm (5.5") cavity (25 mm [1"] air space). No insulation or drywall was used. Note that for smaller cavity widths and/or with the addition of insulation sheathing providing lateral tie support, increased tie system design loads and reduced tie system deflections may be realized.

(vi) Maximum recommended spacing reflects the maximum allowable by CSA-A370-94, ACI/ASCE/TMS/518 and U.B.C. For stud construction, every vertical stud should contain ties. Design will ultimately govern spacing.

 

 
     