SLOTTED
BLOCK TIE (TYPE I)
SPECIFICATION
GUIDELINES
The Slotted Block Plate (Type l) specification length (B)
refers to the standard embedment length into the block, the
specification length (I) refers to the actual thickness of
the insulation plus membrane, while the specification length
(P) refers to the length of projection of the plate into
the air space.
The V-Tie™ specification length (L) should
be selected to provide for placement of the legs of the V-Tie™
at the centerline of brick veneer. The 80 mm (3.1") V-Tie™
is utilized in the Slotted Block Tie (Type I) system consisting
of 25 mm (1") air space and 90 mm (3.5") brick veneer.
The
Insulation Support is standard. |