| CONVENTIONAL
CORRUGATED STRIP TIE

The above dimensions will vary due to manufacturing tolerances,
but that such variation will not exceed the dimensional limits
outlined by CSA Standard A370-04 "Connectors for Masonry"
for "Conventional
Corrugated Strip Ties", ACI/ASCE/TMS/518 and U.B.C.
| Plate Thickness |
0.76 ± 0.05 mm
(0.03" ± 0.002")
|
| Wavelength of corrugations: |
10 mm (0.39")
|
| Depth of corrugations from crest to trough: |
2.5 mm (0.1")
|
| Distance from bottom of hole to bottom of tie: |
6.0 mm (0.24")
|
| Distance from centreline of hole to bottom of tie: |
8.5 mm (0.33")
|
|